ing plate can be scanned within five minutes
at 16 bits. And this high throughput is
achieved without sacrificing superior sensi-
tivity and quantitative accuracy.
The BAS-2500’s range of recommended
applications includes Molecular Biology
(1D electrophoresis, 2D electrophoresis,
DNA & Protein blots and Macro Arrays);
Pharmacokinetics & Toxicology (whole
body autoradiography and thin layer chro-
matography); and Physical and Material
Structural Analysis (X-ray crystallography,
semiconductor wafer check and non-
destructive testing).
Reusable Imaging Plate
is 100x more sensitive
than X-ray film
The Fujifilm IP is a reusable two-dimen-
sional sensor for the detection and storage of
ionizing radiation energy in photostimulable
phosphor crystals. Fujifilm IPs are approxi-
mately 100 times more sensitive than X-ray
film, and have greater quantitative accuracy.
When Fujifilm IPs and the BAS-2500 sys-
tem replace standard X-ray film and process-
ing, your results are available from 10 to 100
times faster. And because Fujifilm IPs are
more sensitive than X-ray film, they capture
information unobtainable using X-ray film
autoradiography. And all of these advantages
can be enjoyed without the need for process-
ing chemicals or a darkroom. While other
phosphor imaging systems have appeared,
Fujifilm scanners and imaging plates remain
the standard by which others are measured.
Fully networkable
All Fujifilm research imaging systems
are easily networked for
seamless integration into
multi-user laboratory envi-
ronments. Ask your repre-
sentative for details.
Data Images, left to right:
1. Fast thin film phase and orientation analysis of Ta on Si with an exposure time of 3 seconds. Sample courtesy of Dr. Sabrina Lee, Watervliet Arsenal, Professor Toh-Min Lu and Dr. Donald Windover,
Rensselaer Polytechnic Institute, Troy, N.Y., U.S.A.
2. Dot blot. Sample courtesy of Assistant Professor Kuniya Abe, Kumamoto University, Faculty of Medicine, Institute of Molecular Embryology and Genetics, Department of Developmental Genetics.
3. Thin film phase and orientation analysis of Ta on Si with an exposure time of 10 minutes. Sample courtesy of Dr. Sabrina Lee, Watervliet Arsenal, Professor Toh-Min Lu and Dr. Donald Windover,
Rensselaer Polytechnic Institute, Troy, N.Y., U.S.A.
4. Whole-body rat slice. Fujifilm file image.
The BAS-2500 incorporates Fujifilm’s
proprietary light guide and is manufactured to
ISO 9002 standards for maximum efficiency
and quality.